Causes of damage to 35KV current transformers
Release time:
2024-09-14
35KV current transformers are widely used electrical devices in power systems. If one can correctly understand this equipment, follow the standard installation procedures, and perform regular maintenance, the likelihood of damage can be reduced. Of course, if damage is discovered, there is no need to worry. A careful inspection should be conducted; if the damage is not severe, appropriate repairs can allow it to continue in use. If the damage is serious and repair costs are high, it is recommended to replace it with a new one.
1. Environmental Factors Impact
The impact of environmental factors needs to be considered during the use of 35KV current transformers. For example, 35KV current transformers are usually installed outdoors or in substations, facing harsh weather conditions and significant variations in temperature and humidity. They are easily affected by extreme weather conditions and natural factors, which can lead to damage to the 35KV current transformers.
Causes of Damage to 35KV Current Transformers
2. Presence of Overload Current
Overload current is one of the common causes of damage to 35KV current transformers. During the operation of the power system, there often occurs excessively high current flowing in from outside the power system, exceeding the rated load value of the 35KV current transformer. When the current continuously exceeds the rated value, long-term accumulation can cause the core to saturate with excessive magnetic flux, making the 35KV current transformer prone to damage.
3. Equipment Aging
35KV current transformers also experience the issue of equipment aging during use. Long-term use and improper maintenance can lead to the 35KV current transformer reaching its lifespan limit, causing circuit failures and increased measurement errors, which affect the stability of the power system operation. Therefore, timely replacement of aging 35KV current transformers is one of the important steps to ensure power safety and stability.
Causes of Damage to 35KV Current Transformers
4. Improper Installation Methods
During the installation of 35KV current transformers, it is important to pay attention to whether the operation methods are correct. Improper installation can lead to poor circuit closure of the 35KV current transformer, affecting the connectivity of the circuit. Attention should be paid to installation standards, selection of installation location and height, placement position, and fixing methods during the operation.
35KV current transformers are widely used electrical equipment in power systems. If one can correctly understand this equipment, follow the standard installation steps, and perform regular maintenance, the probability of damage can be reduced. Of course, if damage is found, there is no need to worry. Carefully check; if the damage is not severe, it can continue to be used with appropriate repairs. If the damage is severe and repair costs are high, it is recommended to replace it directly.